INSTRUMENTS WITH A DIGITAL SOUL

Country: United Kingdom

Promotions

AX-CP-03-R

Clip-on probe; with puncturing point; 10A; red; 4mm; Ø: 4mm

AX-TLS-003A

Test lead; silicone; 1m; 10A; red and black

AX-155

Digital multimeter; 2x/s; VDC: 0,1m÷400m/4/40/400/1000V; 375g

AX-TL-4B1-R

Test lead; 1m; red; 19A; Cond.cross sec: 1mm2

AX-TLP-TW-01

Test tweezers; 0.4m; black; Type: with protection

AX-18B

Digital multimeter; LCD (6000) 14mm, with a backlit; 3x/s

AX-CP-03-B

Clip-on probe; with puncturing point; 10A; black; 4mm; Ø: 4mm

AX-TLP-003

Test lead; PVC; 1.2m; 10A; red and black; 2x test lead

AX-CR-4PM-BL

Crocodile clip; 15A; blue; Grip capac: max.12mm; Socket size: 4mm

AX-588B

Digital multimeter; LCD 3,5 digit 28mm; -40÷1000°C; 3V

AXIOMET Catalogue

Download Catalogue
(ver. 6)
PDF (12,9 MB)

Product specifications
Type of meter:
digital multimeter
Measurement:
frequency, AC voltage, DC voltage, capacitance, AC current, DC current, resistance
Measuring instrument features:
  • auto and manual ranging
  • automatic power-off
  • HOLD function
  • MIN/MAX function
  • AUTOSCAN function for detection of tested component
  • non-contact voltage detector
  • low battery indicator
Kind of display used:
LCD (6000), with a backlit
Sampling:
3x/s
DC voltage measuring range:
0,1m...600m/6/60/600/1000V
DC voltage measuring accuracy:
±(0.8% + 5 digits)
AC voltage measuring range:
0,1m...600m/6/60/600/1000V
AC voltage measuring accuracy:
±(1% + 3 digits)
DC current measuring range:
0,1µ...600µ/6m/60m/600m/10A
DC current measuring accuracy:
±(1,5% + 3 digits)
AC current measuring range:
0,1µ...600µ/6m/60m/600m/10A
AC current measuring accuracy:
±(1,8% + 8 digits)
True effective value measurement:
True RMS
Resistance measuring range:
0,1...600/6k/60k/600k/6M/60MΩ
Resistance measuring accuracy:
±(1,2% + 2 digits)
Capacitance measuring range:
1p...6n/60n/600n/6µ/60µ/600µ/6m/60mF
Capacitance measuring accuracy:
±(3% + 3 digits)
Frequency measuring range:
0,001...6k/10kHz
Frequency measuring accuracy:
±(0.05% + 8 digits)
Diode test:
1mA, 2,8V
Continuity test:
acoustic signal for R<30Ω
Operating temperature:
0...40 °C
Pollution degree:
2
Storage temperature:
-10...60 °C
Overall dimensions (W x D x H):
90x40x190 mm
Weight with battery:
500 g
Power supply:
1 battery 9V 6F22, set without battery
Standard equipment:
test leads
Optional equipment:
  • test leads AX-TL-4B1-B
  • test leads AX-TL-4B1-BL
  • test leads AX-TL-BNC-4BP2
  • test leads AX-TLP-001
  • test leads AX-TLP-001T
  • test leads AX-TLP-002
  • test leads AX-TLP-003
  • test leads AX-TLS-001B
  • test leads AX-TLS-002B
  • test leads AX-TLS-003A
  • test leads AX-TLS-004A
  • test leads AX-TLS-005A
  • test leads AX-TLS-007S
  • test leads PPOM-14
  • test tweezers AX-TLP-TW-01
Conform to the norm:
EN61010 1000V CAT III, EN61010 600V CAT IV
Additional information
Gross weight:
0.78 kg