Measuring instruments for controlling industrial processes. Depending on the model, they enable precise measuring of signals and setting up various benchmarks.
Parameters | AX-C800 | AX-C850 | AX-C830 |
---|---|---|---|
Net price from
159105 HUF
|
Net price from
112953 HUF
|
Net price from
90303 HUF
|
|
Type of meter | calibrator | calibrator | calibrator |
Kind of calibrator |
|
RTD | thermocouple |
Kind of display used | LCD | LCD | LCD |
DC voltage measuring range |
|
||
DC voltage measuring accuracy | ±(0.02% + 2 digit) | ±(0.025% + 2 digit) | |
DC current measuring range | 0...24mA | ||
DC current measuring accuracy | ±(0.015% + 2 digit) | ||
Voltage source |
|
||
Voltage source accuracy | ±(0,02% + 2 digits) | ||
Current source accuracy | ±(0,015% + 2 digits) | ||
Current source | 0...24mA | ||
Dimensions | 204x99x46mm | 205x98x46mm | 205x98x46mm |
Power supply | battery GR03 AAA 1,5V x6 | battery GR03 AAA 1,5V x6 | battery GR03 AAA 1,5V x6 |
Measuring instrument features |
|
|
|
Standard equipment |
|
|
|
Measurement |
|
resistance | temperature |
Protection |
|
||
Resistance to | fall from 1m height | fall from 1m height | |
Battery/ rechargeable battery | battery GR03 AAA 1,5V x6 | battery GR03 AAA 1,5V x6 | battery GR03 AAA 1,5V x6 |
Illumination | yes | yes | yes |
Industrial calibrators with a built-in multimeter are multifunctional instruments for measuring voltage, current, resistance, and setting up and simulating mA currents. They allow conducting manual or automatic tests with SAW or RAMP signals. The signal can be changed in two ways: smoothly or sharply with steps given in %. The 24V loop power supply facilitates operations, as it eliminates the need for additional power source. A built-in 250Ω resistor enables you to control the processes in devices that are compliant with the HART protocol.
Parameters | AX-C705 | AX-C708 | AX-C709 |
---|---|---|---|
Type of meter | calibrator | multimeter calibrator | multimeter calibrator |
Kind of calibrator | loop | ||
Kind of display used | LCD | LCD | LCD |
Display parameters | (5000) | (3999) | (3999) |
DC voltage measuring range | 0...50V |
|
|
DC voltage measuring accuracy | ±(0.5% + 4 digit) | ±(0.2% + 4 digit) | ±(0.2% + 4 digit) |
AC voltage measuring range | 0...500V |
|
|
AC voltage measuring accuracy | ±(1.5% + 4 digit) | ±(0.5% + 4 digit) | ±(0.5% + 4 digit) |
DC current measuring range | 0...20mA |
|
|
DC current measuring accuracy | ±(0.2% + 4 digit) | ±(0.2% + 4 digit) | ±(0.2% + 4 digit) |
Resistance measuring range | 5kΩ |
|
|
Resistance measuring accuracy | ±(0.5%+4 digit) | ±(0.2%+4 digit) | ±(0.2%+4 digit) |
Current source | 0...20mA | -22...22mA | 0...20mA |
Test | diodes | ||
Continuity test | acoustic indication |
|
|
Operating temperature | 0...40°C | ||
Dimensions | 180x90x47mm | 205x95x42mm | 205x95x42mm |
Power supply | battery LR6 AA 1,5V x2 | battery R03 AAA 1,5V x4 | battery LR03 AAA 1,5V x4 |
Measuring instrument features |
|
|
|
Measurement |
|
|
|
Conform to the norm |
|
|
|
Sampling | 2,5x/s | ||
Battery/ rechargeable battery | none | none | none |
Loop calibrators are devices capable of generating currents in the mA range. They are used for simulating and measuring signals of elements working in current loops. The signal can be changed smoothly or in % steps. In step mode the output current for 0% and 100% of range can be set by the operator.
Parameters | AX-C605 |
---|---|
Net price from
70366 HUF
|
|
Type of meter | calibrator |
Kind of calibrator | loop |
Kind of display used | LCD |
Display parameters | 4,5 digit (19999) |
DC voltage measuring range | 0...28V |
DC current measuring range | 0...22mA |
Current source | 0...22mA |
Operating temperature | 0...50°C |
Dimensions | 180x90x47mm |
Power supply | battery LR6 AA 1,5V x2 |
Measuring instrument features |
|
Measurement |
|
Conform to the norm |
|
Current measuring resolution | 1µA |
Voltage measuring resolution | 1mV DC |
Battery/ rechargeable battery | none |
DC current measuring accuracy | ±(0.02% + 4µA) |