INSTRUMENTS WITH A DIGITAL SOUL

AX-58xB AXIOMET digital multimeters – measurements in compliance with the IEC standard

When we compare parameters of modern digital multimeters, we can be easily attracted with their measurement precision or powerful set of functionalities, but we totally forget about the most important thing – safety. The level of protection offered by a particular meter depends primarily on the type of cables insulation and on other factors described in the PN-EN61010 standard.

According to the PN-EN61010 standard, the safety category describes conditions for permitted use of a device:

  • CAT I: for electronic measurements,
  • CAT II: for single-phase energy receivers,
  • CAT III: for 3-phase distribution systems,
  • CAT IV: for measurements of 3-phase voltage in utility connections and installations outside of buildings.

Unfortunately, multimeters compliant with the CAT IV safety category are usually very expensive. Their manufacturers often equip them with numerous advanced functionalities, and hence their price is high. However, very often what we actually need is a robust design and convenience of use, not state-of-the-art functionalities.

The AX-582B, AX-585B, and AX-588B AXIOMET digital multimeters fully satisfy all these requirements. These are the cheapest AXIOMET multimeters which fulfill CAT IV requirements. Moreover, they are equipped with a shock-resistant holster and they are offered together with an optional soft case. These digital multimeters are solid and they are powered from a 9V battery (low battery power is signaled by the device.) What is more, AX-58XB AXIOMET multimeters are equipped with LCD backlit displays, thanks to which it is possible to use them at night and in dark spaces. They also have a high resistance threshold for continuity tests: 70Ω.

Other parameters are similar to those of other AXIOMET multimeters:

  • AX-588B and AX-585B allow frequency, capacitance, and temperature measurements.
  • AX-588B has enhanced range (up to 2GΩ) of resistance measurement.
  • AX-585B allows for **TrueRMS** measurement. It also provides the most accurate readings thanks to a large, 4.5 digit display (the max. displayed value is 19999) with 32mm digit height.
  • AX-582B allows for phase wire detection and, like AX-588B, for measurement of hFE parameter of transistors.

Parameters AX-585B AX-582B AX-588B
AX-585B
Net price from 48.45 EUR
AX-582B
Net price from 29.98 EUR
AX-588B
Net price from 49.97 EUR
Type of meter digital multimeter digital multimeter digital multimeter
Measurement
  • AC current
  • AC voltage
  • capacitance
  • DC current
  • DC voltage
  • frequency
  • resistance
  • temperature
  • AC current
  • AC voltage
  • capacitance
  • DC current
  • DC voltage
  • resistance
  • transistors' gain hFE
  • AC current
  • AC voltage
  • capacitance
  • DC current
  • DC voltage
  • frequency
  • inductance
  • resistance
  • temperature
  • transistors' gain hFE
Kind of display used LCD LCD LCD
Display parameters 4,5 digit (19999) 3,5 digit 3,5 digit
Sampling 3x/s
DC voltage measuring range
  • 10µV...200mV
  • 2V
  • 20V
  • 200V
  • 1kV
  • 0.1...200mV
  • 2V
  • 20V
  • 200V
  • 1kV
  • 0.1...200mV
  • 2V
  • 20V
  • 200V
  • 1kV
DC voltage measuring accuracy ±(0.1% + 5 digit) ±(0.5% + 3 digit) ±(0.5% + 3 digit)
AC voltage measuring range
  • 100µV...2V
  • 20V
  • 200V
  • 750V
  • 1mV...2V
  • 20V
  • 200V
  • 750V
  • 0.1...200mV
  • 2V
  • 20V
  • 200V
  • 750V
Bandwidth for AC voltage measurements 40...400Hz 40...200Hz
  • 40Hz...100Hz @ ≤750V
  • 40Hz...400Hz @ ≤200V
DC current measuring range
  • 10nA...200µA
  • 2mA
  • 20mA
  • 200mA
  • 20A
  • 0.1...200µA
  • 20µA
  • 20mA
  • 200mA
  • 2A
  • 20A
  • 1µA...2mA
  • 20mA
  • 200mA
  • 20A
DC current measuring accuracy ±(0.5% + 4 digit) ±(0.8% + 4 digit) ±(0.8% + 3 digit)
AC current measuring range
  • 1µA...20mA
  • 200mA
  • 20A
  • 0.1...200mA
  • 2A
  • 20A
  • 1µA...2mA
  • 20mA
  • 200mA
  • 20A
AC current measuring accuracy ±(1.5% + 25 digit) ±(2% + 5 digit) ±(1% + 5 digit)
Bandwidth for AC current measurements 40...200Hz 40...200Hz 40...200Hz
True effective value measurement True RMS AC True RMS
Resistance measuring range
  • 1...200Ω
  • 2kΩ
  • 20kΩ
  • 200kΩ
  • 2MΩ
  • 200MΩ
  • 100mΩ...200Ω
  • 2kΩ
  • 20kΩ
  • 200kΩ
  • 2MΩ
  • 200MΩ
  • 100mΩ...200Ω
  • 2kΩ
  • 20kΩ
  • 200kΩ
  • 2MΩ
  • 20MΩ
  • 2GΩ
Capacitance measuring range
  • 1pF...20nF
  • 2µF
  • 2mF
  • 10pF...20nF
  • 2µF
  • 200µF
  • 10pF...20nF
  • 2µF
  • 20µF
  • 200µF
Capacitance measuring accuracy ±(3.5%+ 10 digit) ±(2.5%+ 20 digit) ±(2.5%+ 20 digit)
Frequency measuring range
  • 1...20kHz
  • 200kHz
  • 1...2kHz
  • 20kHz
  • 200kHz
  • 2MHz
  • 10MHz
Frequency measuring accuracy ±(3%+150 digit) ±(0.5%+4 digit)
Temperature measuring range -10...1000°C -40...1000°C
Temperature measurement accuracy ±(0.8% + 40 digit) ±(1% + 4 digit)
Resistance measuring accuracy ±(0.4%+5 digit) ±(0.8%+3 digit) ±(0.8%+3 digit)
Temperature measurement resolution 0.1°C
Diode test 1mA @3V 1mA @3V 1mA @3V
Continuity test
  • acoustic indication
  • <70Ω
  • acoustic indication
  • <70Ω
  • acoustic indication
  • <70Ω
Weight with battery 400g 375g 400g
Power supply battery 6F22 9V x1 battery 6F22 9V x1 battery 6F22 9V x1
Standard equipment
  • drop-like K-type probe with banana clips 4mm TP-09
  • test leads
  • adapter for capacitance and transistors' gain (hFE) measurement
  • test leads
  • adapter for capacitance and transistors' gain (hFE) measurement
  • drop-like K-type probe with banana clips 4mm TP-09
  • test leads
Optional equipment
  • AX-58P soft cover
  • test leads AX-TL-4B1-B
  • test leads AX-TL-4B1-BL
  • test leads AX-TL-4B1-R
  • test leads AX-TL-BNC-4BP2
  • test leads AX-TLP-001
  • test leads AX-TLP-001T
  • test leads AX-TLP-002
  • test leads AX-TLP-003
  • test leads AX-TLS-001B
  • test leads AX-TLS-002B
  • test leads AX-TLS-003A
  • test leads AX-TLS-004A
  • test leads AX-TLS-005A
  • test leads AX-TLS-007S
  • test tweezers AX-TLP-TW-01
  • AX-58P soft cover
  • test leads AX-TL-4B1-B
  • test leads AX-TL-4B1-BL
  • test leads AX-TL-4B1-R
  • test leads AX-TL-BNC-4BP2
  • test leads AX-TLP-001
  • test leads AX-TLP-001T
  • test leads AX-TLP-002
  • test leads AX-TLP-003
  • test leads AX-TLS-001B
  • test leads AX-TLS-002B
  • test leads AX-TLS-003A
  • test leads AX-TLS-004A
  • test leads AX-TLS-005A
  • test leads AX-TLS-007S
  • test leads PPOM-14
  • test tweezers AX-TLP-TW-01
  • AX-58P soft cover
  • test leads AX-TL-4B1-B
  • test leads AX-TL-4B1-BL
  • test leads AX-TL-4B1-R
  • test leads AX-TL-BNC-4BP2
  • test leads AX-TLP-001
  • test leads AX-TLP-001T
  • test leads AX-TLP-002
  • test leads AX-TLP-003
  • test leads AX-TLS-001B
  • test leads AX-TLS-002B
  • test leads AX-TLS-003A
  • test leads AX-TLS-004A
  • test leads AX-TLS-005A
  • test leads AX-TLS-007S
  • test leads PPOM-14
  • test tweezers AX-TLP-TW-01
Conform to the norm
  • CAT IV 600V
  • EN 61010
  • CAT IV 600V
  • EN 61010
  • CAT IV 600V
  • EN 61010
Related items
  • 5790D
  • 5793D
  • 5794D
  • 5795D
  • 5797D
  • BKP60
  • EX871515
  • EX881602
  • EX881603
  • EX881605
  • PKT-PTA
  • PKT-PTF-10
  • PKT-PTF-20
  • PKT-PTF-25
  • PKT-PTF-30
  • PKT-PTF-40
  • PKT-PTF-50
  • PKT-PTF-55
  • PKT-PTF-56
  • PKT-PTF-60
  • SE027
  • SE028
  • SE029
  • SE030
  • SE031
  • SE059
  • SE060
  • SE061
  • SE062
  • SE001
  • SE002
  • SE003
  • SE004
  • SE000
  • TESTO-06020393
  • TESTO-06020645
  • TESTO-06024592
  • TESTO-06024892
  • TESTO-06280020
  • TESTO-06281292
  • TESTO-06287533
  • TP200
  • TP400
  • TP870
  • TP873
  • TP873-5M
  • TP882
  • TP-111
  • TP-112
  • TP-02
  • TP-03
  • TP-04
  • TP-06
  • TP-08
  • TP-09
  • TPK-59
  • TPK-62
  • UTT10K
  • UTT12
  • 5790D
  • 5793D
  • 5794D
  • 5795D
  • 5797D
  • BKP60
  • EX871515
  • EX881602
  • EX881603
  • EX881605
  • PKT-PTA
  • PKT-PTF-10
  • PKT-PTF-20
  • PKT-PTF-25
  • PKT-PTF-30
  • PKT-PTF-40
  • PKT-PTF-50
  • PKT-PTF-55
  • PKT-PTF-56
  • PKT-PTF-60
  • SE027
  • SE028
  • SE029
  • SE030
  • SE031
  • SE059
  • SE060
  • SE061
  • SE062
  • SE001
  • SE002
  • SE003
  • SE004
  • SE000
  • TESTO-06020393
  • TESTO-06020645
  • TESTO-06024592
  • TESTO-06024892
  • TESTO-06280020
  • TESTO-06281292
  • TESTO-06287533
  • TP200
  • TP400
  • TP870
  • TP873
  • TP873-5M
  • TP882
  • TP-111
  • TP-112
  • TP-02
  • TP-03
  • TP-04
  • TP-06
  • TP-08
  • TP-09
  • TPK-59
  • TPK-62
  • UTT10K
  • UTT12
Dimensions (W x H x D) 97x189x35mm 97x189x35mm 97x189x35mm
Measuring instrument features
  • automatic power-off
  • HOLD function
  • impact resistant holster
  • low battery indicator
  • manual ranging
  • universal
  • automatic power-off
  • detects line wire (acoustic and optical indication)
  • HOLD function
  • impact resistant holster
  • low battery indicator
  • manual ranging
  • universal
  • automatic power-off
  • enhanced range of resistance measurement to 2000MΩ
  • impact resistant holster
  • low battery indicator
  • manual ranging
  • PEAK HOLD function
  • universal
Battery/ rechargeable battery none none none
Display height 1 32mm 28mm 28mm


All AX-58xB digital multimeters can be used to make basic measurements. They are of the same dimensions and they are delivered with appropriate test probes.