INSTRUMENTS WITH A DIGITAL SOUL

Calibration of devices for measuring electrical quantities

Calibrators:

Measuring instruments for controlling industrial processes. Depending on the model, they enable precise measuring of signals and setting up various benchmarks.

Parameters AX-C800 AX-C850 AX-C830
AX-C800
Net price from 1673.59 PLN
AX-C850
Net price from 1188.12 PLN
AX-C830
Net price from 949.87 PLN
Type of meter calibrator calibrator calibrator
Kind of calibrator
  • current
  • voltage
RTD thermocouple
Kind of display used LCD LCD LCD
DC voltage measuring range
  • 0...100mV
  • 10V
DC voltage measuring accuracy ±(0.02% + 2 digit) ±(0.025% + 2 digit)
DC current measuring range 0...24mA
DC current measuring accuracy ±(0.015% + 2 digit)
Voltage source
  • 0...100mV
  • 0...10V
Voltage source accuracy ±(0,02% + 2 digits)
Current source accuracy ±(0,015% + 2 digits)
Current source 0...24mA
Dimensions 204x99x46mm 205x98x46mm 205x98x46mm
Power supply battery GR03 AAA 1,5V x6 battery GR03 AAA 1,5V x6 battery GR03 AAA 1,5V x6
Measuring instrument features
  • 24V loop supply voltage
  • measurement and sourcing of current in mA and A
  • measurement or generation of voltage in mV and V
  • simultaneous readout in mA and % of range
  • low battery indicator
  • measures by means of 2-, 3- or 4-wire method
  • operates with 7 types of RTDs: Pt10 (385), Pt50, Pt100, Pt200, Pt500, Pt1000, Pt100 (JIS)
  • output signal simulation
  • high accuracy
  • impact resistant holster
  • measures and simulates
  • operates with thermocouple types: J, K, T, E, R, S, B, N
  • power supply socket
Standard equipment
  • case
  • insulated crocodile clips
  • set of test leads with probes
  • case
  • insulated crocodile clips
  • test leads
  • case
  • K-terminal
Measurement
  • DC current
  • DC voltage
resistance temperature
Protection
  • anti-overload OPP
  • anti-overvoltage OVP
Resistance to fall from 1m height fall from 1m height
Battery/ rechargeable battery battery GR03 AAA 1,5V x6 battery GR03 AAA 1,5V x6 battery GR03 AAA 1,5V x6
Illumination yes yes yes

Multimeter calibrators:

Industrial calibrators with a built-in multimeter are multifunctional instruments for measuring voltage, current, resistance, and setting up and simulating mA currents. They allow conducting manual or automatic tests with SAW or RAMP signals. The signal can be changed in two ways: smoothly or sharply with steps given in %. The 24V loop power supply facilitates operations, as it eliminates the need for additional power source. A built-in 250Ω resistor enables you to control the processes in devices that are compliant with the HART protocol.

Parameters AX-C705 AX-C708 AX-C709
AX-C705 AX-C708 AX-C709
Type of meter calibrator multimeter calibrator multimeter calibrator
Kind of calibrator loop
Kind of display used LCD LCD LCD
Display parameters (5000) (3999) (3999)
DC voltage measuring range 0...50V
  • 0.01...40mV
  • 400mV
  • 4V
  • 40V
  • 400V
  • 0.01...40mV
  • 400mV
  • 4V
  • 40V
  • 400V
DC voltage measuring accuracy ±(0.5% + 4 digit) ±(0.2% + 4 digit) ±(0.2% + 4 digit)
AC voltage measuring range 0...500V
  • 10µV...400mV
  • 4V
  • 40V
  • 400V
  • 10µV...400mV
  • 4V
  • 40V
  • 400V
AC voltage measuring accuracy ±(1.5% + 4 digit) ±(0.5% + 4 digit) ±(0.5% + 4 digit)
DC current measuring range 0...20mA
  • 10µA...40mA
  • 400mA
  • 10µA...40mA
  • 400mA
DC current measuring accuracy ±(0.2% + 4 digit) ±(0.2% + 4 digit) ±(0.2% + 4 digit)
Resistance measuring range 5kΩ
  • 100mΩ...400Ω
  • 4kΩ
  • 40kΩ
  • 400kΩ
  • 4MΩ
  • 40MΩ
  • 100mΩ...400Ω
  • 4kΩ
  • 40kΩ
  • 400kΩ
  • 4MΩ
  • 40MΩ
Resistance measuring accuracy ±(0.5%+4 digit) ±(0.2%+4 digit) ±(0.2%+4 digit)
Current source 0...20mA -22...22mA 0...20mA
Test diodes
Continuity test acoustic indication
  • acoustic indication
  • <50Ω
  • acoustic indication
  • <50Ω
Operating temperature 0...40°C
Dimensions 180x90x47mm 205x95x42mm 205x95x42mm
Power supply battery LR6 AA 1,5V x2 battery R03 AAA 1,5V x4 battery LR03 AAA 1,5V x4
Measuring instrument features
  • 24V loop supply voltage
  • automatic power-off
  • HART range with loop and built-in 250Ω resistor
  • HOLD function
  • measure, source and simulate current in mA
  • source and simulate 0-20mA or 4-20mA output signal
  • tests in 25% steps and at 100% of signal
  • 5-28V loop supply voltage
  • auto and manual ranging
  • automatic power-off
  • HOLD function
  • low battery indicator
  • auto and manual ranging
  • automatic power-off
  • DC voltage output
  • HOLD function
  • low battery indicator
  • operates with thermocouple types: J, K, T, E, R, S, B, N
  • RTD and resistance simulation
  • square wave output
Measurement
  • AC voltage
  • DC current
  • DC voltage
  • resistance
  • AC current
  • AC voltage
  • DC current
  • DC voltage
  • frequency
  • resistance
  • AC current
  • AC voltage
  • DC current
  • DC voltage
  • frequency
  • resistance
Conform to the norm
  • CAT IV 600V
  • EN 61010
  • CAT II 600V
  • EN 61010
  • CAT II 600V
  • EN 61010
Sampling 2,5x/s
Battery/ rechargeable battery none none none

Loop calibrator:

Loop calibrators are devices capable of generating currents in the mA range. They are used for simulating and measuring signals of elements working in current loops. The signal can be changed smoothly or in % steps. In step mode the output current for 0% and 100% of range can be set by the operator.

Parameters AX-C605
AX-C605
Net price from 740.16 PLN
Type of meter calibrator
Kind of calibrator loop
Kind of display used LCD
Display parameters 4,5 digit (19999)
DC voltage measuring range 0...28V
DC current measuring range 0...22mA
Current source 0...22mA
Operating temperature 0...50°C
Dimensions 180x90x47mm
Power supply battery LR6 AA 1,5V x2
Measuring instrument features
  • 24V loop supply voltage
  • automatic power-off
  • low battery indicator
  • tests in 25% steps and at 100% of signal
Measurement
  • 0-20mA current loop
  • DC current
  • DC voltage
Conform to the norm
  • CAT IV 600V
  • EN 61010
Current measuring resolution 1µA
Voltage measuring resolution 1mV DC
Battery/ rechargeable battery none
DC current measuring accuracy ±(0.02% + 4µA)